Identify the incorrect statements regarding primary standard of titrimetric analysis.
(A) It should be purely available in dry form.
(B) It should not undergo chemical change in air.
(C) It should be hygroscopic and should react with another chemical instantaneously and stoichiometrically.
(D) It should be readily soluble in water.
(E) & can be used as primary standard.
Choose the correct answer from the options given below:
Show answer and solution
Correct answer: Option 2
A primary standard must be obtainable in high purity, stable in air and suitable for accurate weighing. For the aqueous titrations here, it should dissolve readily and react quantitatively with a definite stoichiometry. Thus A, B and D are correct.
It should be nonhygroscopic, so that its weighed mass does not include an uncertain amount of absorbed water. Hence C is incorrect. absorbs moisture and carbon dioxide; may contain impurities and its solutions require standardisation. Neither is used directly as a primary standard. E is also incorrect, so option (2).